Conradweg 24 - 26, Bergen op Zoom

Features

BUILDING AREA*

DC 1 LEASED
Warehouse 18,094 m²
Mezzanine 1,900 m²
Office 430 m²
DC 2 AVAILABLE Q2 2019 onwards
Warehouse 12,213 m²
Mezzanine 1,582 m²
Office 353 m²
DC 3 AVAILABLE
Warehouse 11,758 m²
Mezzanine 1,530 m²
Office 405 m²
Total surface 48,265 m²

*m² mentioned are subject to final delivery leve

LEASE PRICES*

Warehouse € 45.00 per m² per year
Mezzanine € 25.00 per m² per year
Office € 120.00 per m² per year

*Prices are excluding VAT and service costs.

DELIVERY LEVEL

WAREHOUSE

  • ESFR – Sprinkler installation with central water supply point;
  • Smooth concrete floor with evenness class Zeile 4 in compliance with DIN 18,202;
  • Floor loading 4,000 kg/m², expedition room 2,500 kg/m²;
  • The point loading underneath the shelving is 72 kn;
  • Concrete loading space;
  • Free height 10.50 metres;
  • Minimum of 1 dock per 800 m²;
  • Hydraulic dock levellers (8 tons), electrically operable;
  • Electric overhead doors on each loading dock;
  • Dock shelter with bumpers and wheel guidance;
  • Electrically operable overhead doors on ground level measurement 4,000 mm x 4,500 mm;
  • Fire hose reels, in compliance with the requirements set by the fire department;
  • Fire detection and evacuation installation;
  • Connection points battery chargers (5 connections);
  • Sufficient 230v and 400v connections;
  • Light streets in the expedition zone;
  • Building LED-lighting, average of 250 lux, 1 metre above floor surface;
  • Motion detector per hallway zone;
  • Direct ignition heaters (minimum room temperature 5 °C);
  • Sanitary fittings.

OFFICE SPACE

  • Large entrance;
  • Smooth finished floors in the offices;
  • VRF climate system (21°C);
  • Mechanical ventilation system;
  • Ceiling system equipped with integrated LED-lighting (500 lux);
  • Cable ducts for data, phone and internet;
  • Toilet facilities on both floors;
  • Plaster walls;
  • Pantry room on both floors.

OUTERSIDE

  • Brick pavement;
  • Site is closed-off through a 2 metre high double rod fencing;
  • Closable electric access gate(s);
  • Sewer system;
  • Exterior lighting;
  • Connection point for electrical rechargeable passenger cars (2 connections);
  • Ample parking spaces for passenger cars.